Note: The LNB accept a very wide range of values for these voltages, usually
10-14.5V (for 13V) and 15.5-20V (for 18V).
In the
HD
RANGER
Lite
the band and the polarisation selection can be done
from different menus (all the different ways indicate dare equivalent):
Menu Line
External units power supply 13 V, 18 V, 13 V+22kHz, 18 V+22kHz
Configuration
Band: High / Low
Polarization: Vertical / Horizontal
DiSEqC
Band: High / Low
Polarization: Vertical / Horizontal
A3.3
DiSEqC
TM
around the world
The use of DiSEqC
TM
devices requires to know previously which commands are
acknowledged by these ones, since it will determine the wiring diagram of the
different elements, as well as the way as they can be controlled. This information
must be provided by the device manufacturer.
Following appear the DiSEqC
TM
devices more usually installed in the individual
and collective facilities.
A3.4
In the individual facilities
A3.4.1
Tone-burst switcher (2 inputs – 1 output)
Figure A3. 1.
It is the simpler DiSEqC
TM
switcher. This one uses the « SAT A/B » commands
and allows to switch between two different Universal LNB: